看了活体转基?钳状电极的用户又看了
虚拟号将180秒后失效
使用微信扫码拨号
活体转基?-钳状电极用于体内药物/基因/蛋白质传递及基因治疗电极-/p>
活体转基?-钳状电极Tweezertrodes是一种可复用的小钳状电极,主要用于体内的药物或基因的传递。电极是一个标准的11.5厘米的小钳子,其尖部为嵌入的不锈钢圆盘状电极,两盘的间隙可调?厘米,并有一个阳极指示器、/p>
活体转基?-钳状电极Tweezertrodes电极有两种规格,45-0118为直径:7mm的电极盘?5-0119为直径:10mm的电极盘
当把感兴趣的分子注射到体内后,用电极盘夹住相关组织,然后给出电脉冲,使孔道开始形成,将分子整合到直接与电极盘接触的组织细胞内、/p>
Tweezertrodes are reusable tweezer-style in vivo electrodes fordrug or gene delivery in animals. Tweezertrodes consist of astandard 11.5 cm tweezer that has been modified with stainlesssteel circular or disk electrodes at the tip. The gap between theelectrode disks may be adjusted from under 1 mm to over 2 cm.Tweezertrodes come in two models. Model 520 has an electrode diskdiameter of 7 mm and Model 522 has a diameter of 10 mm.Tweezertrodes may be cleaned with a mild detergent and sterilizedwith ethanol or ethylene oxide. These electrodes are connected to apulse generator with the Model 524 Connection Cable and arecompatible with most BTX Electroporation System
Applications
Tweezertrodes may be used for many in vivo applications includinggene and drug delivery. Following localized or systemic injectionof the molecule of interest the Tweezertrode electrode disks areused to grasp the tissue of interest. An electroporation pulse isthen given initiating pore formation and incorporation of themolecule into the cells of the tissue in direct contact with theelectrode disks. Suzuki et al. used Tweezertrodes to deliver aGreen Fluorescent Protein (GFP) gene into rat liver. The authorsdemonstrated successful gene transfer and expression in situ.1?Saito and Nakatsuji used a similar electrode to introduce plasmidDNA during ex-utero and in-utero electroporation.7 Sato et al. usedthe Tweezertrode with the T820 to introduce EGFP expressing plasmidin mouse testis.8 Tweezertrodes complement BTX Genetrode Models508 510 Caliper Electrode Models 384 and 384L 2-Needle ArrayModels 530 and 532 as the newest addition to our in vivo electrodeline. The Tweezertrodes can be used to reproduce applicationsrequiring the caliper electrodes including gene therapy,transdermal drug delivery and electroporation therapy.3???
Technical Specifications
Standard Capabilities
Voltage Range: 0V - 200V (Do not use AC current)
Pulse Length Range: 1 ?sec - 200 msec
Physical Characteristics
Model 520
Tweezertrode Length: 11.5 cm
Electrode Diameter: 7 mm
Electrode Material: Stainless steel
Model 522
Tweezertrode Length: 11.5 cm
Electrode Diameter: 10 mm
Electrode Material: Stainless steel
Generator Compatibility ECM T820 630 830 2001
Ordering Information
System Model Available Configurations
520 Tweezertrode 520
Tweezer Electrode with stainless steel plated 7 mm diameterelectrode disk for in vivo applications
523 Tweezertrode 523
Tweezer Electrode with stainless steel plated 10mm diameterelectrode disk for in vivo applications
Accessory Model Description
524 Tweezertrode Connection Cable
References
Suzuki et al. Direct Gene Transfer into Rat Liver Cells by in vivoElectroporation FEBS Letters 425: 436-440 (1998)
BTX Electroporation Protocol PR0363 (1998)
Zhang et al. In vivo transdermal delivery of large molecules bypressure-mediated electroincorporation and electroporation: a novelmethod for drug and gene delivery Bioelectrochemistry andBioenergetics 42: 283-292 (1997)
Dev Giordano and Brown In vivo delivery of gene to rabbit carotidartery by electroporation Third U.S. / Japan Symposium on DrugDelivery Systems (Abstr.) 38 (1995)
Dev Killing cancer cells with a combination of pulsed electricfields and chemotherapeutic agents Cancer Watch 3: 12-14 (1994)
BTX Electroporation Therapy Protocols ECT001-ECT005 (1995)
Saito and Nakatsuji Developmental Biology 240: 237-246 (2001)
Sato et al. Molecular Reproduction and Development 61: 49-56(2002)
暂无数据