看了便携式五合一有毒有害气体监测仪的用户又看亅/p>
虚拟号将 180 秒后失效
使用微信扫码拨号
pGas2000IR100-ASM-5s08便携式五合一有毒有害气体监测?/strong>技术参数:(本款适用于井上、井下、地下电缆井、电缆隧道等环境的有毒有害气体检测)
Gas | Range | Accuracy | Repeatability | Response/T90 | Method |
CH4 | 0 to 4%'/span>CH4(/span> | <0.1% abs,or <5%R | <0.05% | 4.5s | ND IR |
CO | 0.00% to 10.00% | +0.02% abs. or +3% rel. | -0.02%abs. or -2% rel. | 4.5s | RD IR |
10.01% to 15.00% | +/-5% rel. | +/-3% rel. | |||
CO2 | 0.00% to 16.00% | -0.3% abs. or -3%rel. | -0.1% abs. or -2% rel. | 4.5s | ND IR |
O2 | 0-30% | +/-0.1% | +/- 1% | 60s | EC |
VOC | 0 to100 ppm | +/-5% FS | 0.1ppm or <5%rel whichever great | 4.5s |
便携式五合一有毒有害气体监测?/strong>技术指栆
l BD4主机测试ADC分辨玆/span>: 0.025%FS
l BD5主机测试ADC分辨玆/span>: 0.0015%FS
l 电化学探头准确度: 1-2%读数(一?/span>)
l 长期稳定?/span>: +/-10% / (一?/span>)
l 分析器响应时间:< 10ms
l 探头响应时间9/span><1min
l 仪器使用环境: 温度9/span>-10℃~60ℂspan>; 湿度9/span>10%}/span>90%R(无结露(/span>
l 仪器保存环境: 温度9/span> 0℃~50ℂspan>; 湿度9/span>10%}/span>80%R(无结露(/span>
l 电化学探头直接采栶/span>: 温度: 0-40ℂspan>; 压力:<1.1 kgf/cm2
l 供电: 6V充电蓄电江/span>:
l 连续使用时间: >24Hr/每次充电; 电池置放时间1周、/span>
l 气体快速分析或在线分析
l 环境检浊/span>
l 污染源检浊/span>
l 工业工艺现场分析
l 科学研究实验室分枏/span>
仪器特点9/span>
n 内置单片机微机,先进的微机处理技?/span>
n 工作状态稳定,测量精度高,1/4096
n 实时,连续检测工作方弎/span>
n 报警功能发达,自带声光报警器和LCD字符提示
n 内含100多种常见气体的TWA环境毒气报警和STEL短时暴露允许浓度报警数据库,用户也可以自行设置报警限倻/span>
n 自检功能,探头故障报?/span>
n 电源欠压掉电报警
n 快速检测参数和温度值,并进行温度矫正和交叉矫正
n 24组数据记录,可设置自动或手动记录
n 惰性气体软件调零,标准样品或替代品标定
n 全部操作键盘设置,窗口提礹/span>
暂无数据