看了美国GMW粒子束诊断的用户又看亅/p>
虚拟号将 180 秒后失效
使用微信扫码拨号
Bergoz IPCT DC/AC Current Transducer | Bergoz FCT Current Transformer | Bergoz NPCT | ||
High sensitivity for low current. Differential and net current measurements of multiple conductors. Large internal diameter enables high voltage isolation. | The Fast Current Transformer (FCT) is a wideband AC transformer with a rise time down to 175ps and a bandwidth up to 2GHz. | The New Parametric Current Transformer (NPCT) is a zero-flux DC current transformer. | ||
?Peak Current: 10mA .. 5000mA?Resolution: 10uA?Bandwidth: DC 4.2kHz | ?Bandwidth up to 1.75GHz 200-ps risetime?Droop down to 0.1%/s down to 160 Hz lower cutoff freqency?Extra-high sensitivity up to 5 V/A | ?Full scale range from 20mA to 20A controlled by TTL levels?5 A/sqrt(Hz) resolution in every range?1 A/sqrt(Hz) or lower resolution on option | ||
Bergoz CWCT | Bergoz ACCT | Bergoz ICT Turbo-ICT BCM | ||
The CWCT is a current transformer with strict limits on lower and upper cut-off frequencies tailored to the beam RF. | The ACCT is non-interceptive current transformer. | The Integrating Current Transformer (ICT) is a capacitively shorted transformer and a fast read out transformer in a common magnetic circuit designed to measure the charge in a very short pulse with high accuracy. | ||
?Beam repetition frequency 60~500 MHz?Average current with 1 A resolution?Fast beam loss interlock 1 s?Linearity error <1.5%?Beam loss resolution <1 % | ?Output current range range from 10mA to 2A full scale.?Frequency response from 5Hz to 350kHz?DC current up to 1A does not saturate the sensor?Radiation hard sensors available. | ?Integrates a very fast pulse with rise time in the order of picoseconds with no significant loss | ||
Bergoz MX-BPM / LR-BPM | Bergoz S-BPM | Bergoz VWM | ||
The Bergoz Multiplexed Beam Position Monitor (MX-BPM) is an electronics module?/span> | The S-band / L-band Beam Position Monitor (S–BPM) is an electronics module for fast analog processing of beam pickups signals. | The VWM is based on the wire resonant frequency dependence on its tension itself dependent on its temperature | ||
?On-board microstrip filters that elminate the need for costly tubular filters?GaAs switches to provide superior button to button isolation and low insertion loss?On-board systhesized local oscillator | ?Non-interceptive beam position measurement.?Beam charge range > 1000. | ?Transverse profile and position monitor?Fixed multi-wire sensor or moving sensor?For beams: Photon from infrared to keV Electron proton from keV to GeV and Neutrons |
暂无数据