功率(kw):
/重量(kg):
/规格外形(长*?高)9/p>272*272*310mm
看了台式激光粒子计数器的用户又看了
虚拟号将180秒后失效
使用微信扫码拨号
DPC-2611台式激光粒子计数器,采?/span>PULUODY GROUP第七代双激光窄光检测器技术,根据新版GMPISO14644标准进行生产的全新气体监测设备;
技?/span>参数9/span>
传感器:第七双双激光窄光检测器,寿呼/span>>200000欠/span>
测量粒径9/span>A 0.3um?/span>2.5um?/span>10um:/span>
B 0.3um?/span>(0.5/1.0/2.5/5.0)um?/span>10um:/span>
C 0.3um?/span>0.5um?/span>1.0um?/span>2.5um?/span>5.0m?/span>10um:/span>
D 0.5um?/span>1.0um?/span>1.5um?/span>2.0um?/span>2.5um?/span>3.0um:/span>
E 0.5um?/span>1.0um?/span>3.0um?/span>5.0um?/span>10.0um?/span>25.0um:/span>
F 0.10um?/span>0.2um?/span>0.25um?/span>0.5um?/span>0.7um?/span>1.0μm;
粒径通道?*20?/span>
粒径分布误差9/span>≤°/span>30%
浓度示值误差:≤°/span>30%
重复相对偏差9/span>≤°/span>10%FS
重叠误差:当每立方英尹/span>2,000,000个粒子时小于5%
气体检测:可同时检测气体浓度,支持1-3个各种类型的气体传感?/span>
?/span>湾/span>度:标配温湿度传感器
温度范围9/span>-40120ℂ/span>
湿度范围9/span>0-100%RH
检定标准:计数报告符合GB/T16292-1996叉/span>ISO14644-1标准戕/span>GB/T6167-2007 JJF1190-2008
气泵流速:2.83L/min+/span>28.3L/min+/span>50L/min
100L/min(可选):/span>
采样时间9/span>60秒;
检测模式:数量模式PC/升;
质量模式ug/立方米;
净化效率模弎/span>%;三种检测模式可切换
检测方式:定时检测、循环检测可设置
报警方式:自定义数量报警值、质量报警倻/span>
限值报警:RS485信号报警或外接声光报警器
泔/span>觃/span>性:权限管控、审计追踪、电子记录等
吇/span>觃/span>性:符合ISO 21501-4+/span>CE+/span>JIS B9921
吇/span>觃/span>性:符合21 CFR Part 11
报警级别9/span>Class100}/span>Class300,000?/span>(FS209E )戕/span>5}/span>9?/span>(ISO14464-1)
通讯接口9/span>RS232?/span>R485?/span>LAN-USB
存储模式:实时存储、定时存储可设置;可存储数据无限刵/span>
打印模式:可选配微型打印机打印数?/span>
工作温度9/span>545ℂ/span>
工作电源9/span>AC 100-240V, 50 Hz/60 Hz
工作湿度9/span>≣/span>90%RH,无冷凝